Activate FactoryTalk View V7.00
To activate FactoryTalk View V7.00, follow these steps:
- Install Factory Talk View on your computer.
- Launch the Factory Talk Activation Manager application.
- Enter the activation key that you received when you purchased the software.
- Follow the on-screen instructions to complete the activation process.
- Once activation is complete, restart the FactoryTalk View application.
Note: The activation process may require an internet connection to verify the activation key with Rockwell Automationโs activation server. If you encounter any issues during the activation process, contact Rockwell Automationโs support team for assistance.
Here are some additional details to consider when activating FactoryTalk View V7.00:
- Verify that your computer meets the minimum system requirements for Factory Talk View V7.00. This information can be found in the product documentation or on Rockwell Automationโs website.
- Make sure you have administrative privileges on your computer to install and activate FactoryTalk View.
- If you are installing FactoryTalk View on a network, ensure that the network is configured correctly and has access to the internet to complete the activation process.
- If you have previously installed an evaluation version of Factory Talk View, you will need to remove it from your computer before installing the activated version.
- Keep your activation key and any other software license information in a secure location for future reference.
- FactoryTalk View V7.00 requires activation to ensure that you are using a licensed and up-to-date version of the software. Failure to activate the software may result in limited functionality or disruption of your work.
By following these steps and considerations, you should be able to successfully activate FactoryTalk View V7.00.

Make sure to create a copy of the files you modify.
Run -> services.msc
Stop โFactoryTalk Activation Serviceโ
Stop โRockwell Application Servicesโ and all dependencies when ask.
Hexedit C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\flexsvr.exe
Address: E8F0
From: 55 8B EC 83 E4 F8 81 EC
To: 33 C0 40 89 45 FC 48 C3
Hexedit C:\Program Files\Common Files\Rockwell\FTACommon.dll
Address: 2F619
From: 34 02
To: 30 90
If fresh install of rockwell product open ftasystem.lic from C:\Users\Public\Documents\Rockwell Automation\Activations for edit,
copy the following to the file and save:
Rockwell Automation License File
Copyright (C) 2003-2010 All Rights Reserved
SERVER this_host ANY
USE_SERVER
VENDOR flexsvr
FEATURE rsi.master flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:MASTER LICENSEโ SN=0000000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
FEATURE RSLINX.GW flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:RSLINX.EXE GWโ SN=0000000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
FEATURE RS5K_700.exe flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:RS5K_700.exeโ SN=0000000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
FEATURE RS500P.EXE flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:RSlogix 500โณ SN=0000000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
FEATURE RSLgx5P.exe flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:RSLgx5P.exeโ SN=0000000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
FEATURE WED32.EXE flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:WED32.EXEโ SN=0000000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
FEATURE RSARCH.EXE flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:RSARCH.EXEโ SN=0000000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
FEATURE RSARCH.PERS flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:RSARCH.PERSโ SN=0000000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
FEATURE RSVME.STUDIO flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:RSVME.STUDIOโ SN=1564000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
FEATURE RSV.STUDIO flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:RSV.STUDIOโ SN=1564000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
FEATURE PlantPAx_ModelBuilder.exe flexsvr 1.0 permanent 10 VENDOR_STRING=9999999 \
HOSTID=ANY vendor_info=โPRODUCT_NAME:PlantPAx_ModelBuilder.exeโ SN=0000000001 \
SIGN=โ0034 5678 90AB CDEF 1122 3344 5566 7700 FFFF FFFF FFFF \
FFFF FFFF FFFF FFFFโ
Start โFactoryTalk Activation Managerโ -> Tab โAdvancedโ -> press โRefresh Serverโ button -> Tab โManage Activationsโ -> press โRefresh Activationsโ button. Make sure list of activations appeared.
Remove the file ftasystem2.lic from C:\Users\Public\Documents\Rockwell Automation\Activations, if Manager doesnโt find the licenses
Run FactoryTalk View V7.0 and make sure activated successfully.